Voss Engineering, Inc.
6965 N. Hamlin Ave.
Lincolnwood, IL 60712
Phone: 847.673.8900 • Fax: 847.673.1408
Email: info@vossengineering.comWebsite: www.vossengineering.com
All Categories > NEOSORB® (AASHTO Grade Polychloroprene) Bearing Pads  


NEOSORB® (AASHTO Grade Polychloroprene) Bearing Pads





NEOSORB® plain elastomeric (polychloroprene / neoprene) bearing pads are molded or cut to size from larger slabs to provide a low-cost, single element structural bearing. Plain elastomeric bearings are a cost effective option for applications with moderate load transfer and movement requirements. NEOSORB® pads accommodate surface irregularities, vertical load, and rotation through vertical deflection, while longitudinal movement is accommodated through shear deformation. These pads are suitable for use in pre-cast concrete, cast in place concrete, and steel framed structures.

NEOSORB® is available in all 3 standard AASHTO durometers: 50, 60, and 70, widths up to 48", and lengths up to 49 feet (+/- 1 ft). NEOSORB® is typically available from stock in the following thickness: 1/8", 1/4", 1/2", 3/4", and 1".

For pad sizing and selection in the absence of project specifications or owner design criteria, Voss Engineering, Inc. recommends following AASHTO Section 14 Design Specifications for plain elastomeric bearings (PEP).







NEOSORB® STANDARD MATERIAL PROPERTIES
Material Property ASTM Standard Test Requirement Polychloroprene Units
50 Duro 60 Duro 70 Duro
Physical Properties D 2240 Hardness 50 ± 5 60 ± 5 70 ± 5 Shore A
D 412 Min tensile strength 2250 (15.5) 2250 (15.5) 2250 (15.5) psi (Mpa)
Min ultimate elongation 400 350 300 %
Heat Resistance D 573 Specified temp. of the test 212 (100) 212 (100) 212 (100) °F (°C)
Aging time 70 70 70 Hours
Max change in durometer hardness 15 15 15 Shore A
Max change in tensile strength -15 -15 -15 %
Max change in ultimate elongation -40 -40 -40 %
Compressive Set D 395 Method B Specified temp. of the test 212 (100) 212 (100) 212 (100) °F (°C)
Max Permissible test (after 22 hrs) 35      
Ozone Resistance D 1149 100 pphm ozone in air by volume 20% strain at 100 °F, ± 2 °F (37.7 °C ± 1 °C) 100 hours, mounting procedure D 518, method A No cracks No cracks No cracks  
Tear Resistance D 624 Die C Minimum pounds per inch 180 180   Lbs/in
Brittleness D 746 Low temperature brittleness at -40° No Failure No Failure    





Print Back